An implant overdenture retained by Locator attachments, with the housings picked up in the laboratory so the retention is consistent from day one.
Locator retention depends on the housing being picked up at the correct angulation. We process the housings in the laboratory on the actual abutment analogs, which avoids chair-side pickup errors and gives predictable retention.
Replacement inserts are documented so the clinician can refresh retention without a new prosthesis.
Technical specifications
| Retention | Locator or Locator R-Tx |
|---|---|
| Implants | 2 to 4 |
| Processing | Laboratory pickup on analogs |
| Turnaround | 8–10 working days |
Indications
- Two-implant mandibular overdentures
- Patients with a flat ridge
- Conversion of a complete denture